Dialog: Input Configuration
Symbol: 
Function: The dialog allows you to assign an input action to an input event and to configure the input action.
Call: Configure button in the Input configuration property
Requirement: An element is selected in the editor.
Are all element properties available?
All properties are available only after you select the Advanced option or the All categories filter in Properties.
Input action: User Management
Dialogs and actions | Configures which one of the possible user management dialogs or which action follows the input event NoteThe dialog used at runtime is configured in the Dialog Settings tab of the Visualization Manager. . See also
Default: Dialogs from the |
Login | The login prompt opens. Default: |
Logout | The current user is logged out. |
Change User Password | The dialog for changing the password opens. Default: |
Open User Configuration | The dialog opens for changing the configuration. Default: |
Input Action: Close Dialog
Dialog | The visualization of type Dialog which will be closed
Example: . Default dialogs of the VisuDialogs library, which is usually integrated in the project.
ImportantThe setting in the object property (Visualization tab) of a visualization determines whether or not a visualization can be used as a dialog. |
Result | Return value which is passed to the dialog by the input action NoteIf more input actions should follow when the dialog is closed, then you can configure these in the input configuration of the element which calls the dialog (. ImportantThe result is an internal variable which cannot be accessed programmatically. The value cannot be read from the IEC code. The value can be used together with the Open dialog input action for a conditional update of the transfer parameters. Selection of the result value
|
Input Action: Open Dialog
Dialog | Name of the visualization (type: Dialog) which will open as a dialog at runtime after the input action has been triggered by the visualization user
NoteThe VisuDialogs library provides standard dialogs.
|
Transfer parameters of the dialog | |
Parameter | Interface parameter as they are declared in the interface editor of the visualization. Example: |
Type | Data type of the parameter as it is declared in the interface editor of the visualization. Example: |
Value | IEC variable (data type corresponds to the data type of the parameter) The value of the variable is passed to the parameter when the dialog opens. Example:
|
An internal outcome of the dialog is set. This controls the updating of the transfer parameters. | |
Update | When the dialog is closed, the transfer parameters will be updated if necessary. Whether or not this is done depends on the result value which has been specified in the Close dialog input action. You configure which result values trigger the update here in the Open dialog input action. ImportantThe parameters are updated before the dialog is closed. Until then, the transfer values are stored temporarily. They are stored as a copy, not as a reference. ImportantThe result is an internal variable which cannot be accessed programmatically. The value cannot be read or written from the IEC code. |
Result: None |
|
Result: OK |
|
Result: Cancel |
|
Result: Abort |
|
Result: Retry |
|
Result: Ignore |
|
Result: Yes |
|
Result: No |
|
Open dialog modal |
|
Position to Open | Initial position of the opening dialog relative to the calling visualization |
Centered |
|
Position |
Note: Use the corresponding input options for specifying the position in the X-direction and the Y-direction. |
X | Horizontal X-position for the upper left corner of the opening dialog Input options:
|
Y | Vertical Y-position for the upper left corner of the opening dialog Input options:
|
Input Action: Change Language
Client-dependent language
The language can be switched individually for each client. The requirement is that the CODESYS Visualization add-on is installed in at least version 4.7.0.0 and the runtime system in version >= V3.5 SP20. When the visualization is started, it is displayed in the language set in the browser (for example, de or en). This language must be available in the project. If the language is not available, then the default texts are displayed.
In version 4.6.0.0 and lower, the language was switched for all clients simultaneously.
Language code
Use the ISO 639 code (for example, de, en, it, zh-CHS) to name a language which exists in the visualization.
Language | Language to which the current visualization client is switched Example:
|
Input action: Change Shown Visualization
Visualization that is shown at the user input | |
Assign | Visualization that is selected from all available visualizations in the project or libraries. Example: |
Assign expression | Variable ( Example: |
The order in which visualizations are displayed by user inputs is saved internally. The following options use this information. | |
Previous shown visualization |
Requirement: A visualization switch has already occurred. |
Next shown visualization |
Requirement: A visualization switch has already occurred which was called by Previous shown visualization. |
Input action: Execute Command
Commands are listed here with transfer parameters that the visualization processes when an input event occurs.
Configure commands | ![]()
Click the |
![]() | The command in Configure commands is added to the list. |
![]() | The command is removed. Requirement: A command is selected. |
The order in the list defines the order of execution. | |
![]() | The selected command is moved down one position in the list. |
![]() | The selected command is moved up one position in the list. |
Command | 1st parameter | 2nd parameter |
|
|
|
EXE file that is executed on the controller The program is executed on the PLC and therefore it must not be interactive or have any user interfaces. It is possible, for example, for a program to copy a file. | Program name with directory as a string in single straight quotation marks | Arguments of the program as a string in single straight quotation marks Example: Name of the file that the program opens |
Command | 1. Parameters | 2. Parameters |
|
|
|
EXE file that is executed on the display variant. Exception: WebVisu. The program is executed within the context of the display variant. After this, the program may be interactive and have a user interface. | Program name with directory as | Arguments of the program as Example: Name of the file that the program opens |
Important
If the visualization is displayed as a CODESYS WebVisu, then no program (EXE file) can be started.
Command | 1. Parameters | 2. Parameters |
|
|
|
The visualization navigates to the web page of the URL. Requirement: The visualization is executed as a CODESYS WebVisu. | . URL
| If a parameter is not specified, then the web page is displayed in a new window or a new tab. If |
Command | 1st parameter | 2nd parameter |
|
|
|
. Name of the recipe definition
| . Name of the recipe
| |
At visualization runtime, the controller reads the actual values from the variables of the recipe definition and writes them to the specified recipe. The values are saved implicitly (to a file on the controller) and shown in the recipe definition in the Recipe Manager of CODESYS. In other words, the recipe which is managed in CODESYS is updated with values from the controller. | ||
Command | 1. Parameters | 2. Parameters |
|
|
|
. Name of the affected recipe definition
| . Name of the recipe (from the recipe definition)
| |
At visualization runtime, the values of the recipe are written to the variables on the controller as they are in the Recipe Manager. | ||
Command | 1. Parameters | 2. Parameters |
|
|
|
. Name of the affected recipe definition
| . Name of the affected recipe that is updated and saved to a file
Optional parameter: If you do not specify a transfer parameter here, then the values from the recipe variables are saved only the file that is specified later. The implicit recipe files are not updated. | |
At visualization runtime, the Save Recipe as dialog opens and prompts the user for a file name and a storage location on the controller. The file name must not be The user can then save the file that includes the actual values from the recipe variables. If a transfer parameter is not specified in the 2nd parameter, then the file is saved without changing an implicit recipe file. If a transfer parameter is given in the 2nd parameter, then the implicit recipe file is also updated. Note: If the Save recipe changes to recipe files automatically option is selected in the Recipe Manager – General tab, then the recipe definition in CODESYS and the implicit recipe files are kept the same automatically. Note: Implicit (automatically generated) recipe files exist on the controller with names in the following syntax: | ||
Command | 1st parameter | 2nd parameter |
|
|
|
. Name of the affected recipe definition
| . Name of the affected recipe
| |
At visualization runtime, the Load Recipe dialog opens. It provides the visualization user with a file list that is located in the file system of the controller and filters by the extension Requirement: The file was created with the | ||
Command | 1. Parameters | 2. Parameters |
|
|
|
. Name of the affected recipe definition
| . Name of the new recipe
| |
At visualization runtime, a new recipe is created in the given recipe definition. | ||
Command | 1. Parameters | 2. Parameters |
|
|
|
. Name of the affected recipe definition
| . Name of the recipe
| |
At visualization runtime, the specified recipe is deleted from the recipe definition. | ||
Command | 1. Parameters | 2. Parameters |
| Optional: File name for the visualization screen to be printed (example: "Start screen") | A second parameter cannot be specified for the |
The default Printer dialog opens while the visualization is running. In the dialog, you select a printer and configure additional print settings. When you confirm the dialog, the currently displayed visualization screen is printed. NoteThe command can be executed in the TargetVisu only. | ||
Input action: Switch Frame Visualization
When the input event occurs, the display switches to another visualization within one frame.
Frame selection type | |
Switch local visualization | The Frame Selection group is visible. |
Switch to any visualization | The Frame and visualization selection group is visible. |
Requirement: Switch local visualization is selected. | |
Frame selection | List of all frames that contain the active visualization. The referenced visualizations are listed below each frame, as determined in the References property of the respective frame. Example: ![]() |
Assign selection | The selection in the Frame selection input field is accepted. Then it appears in the Selected frame and Selected visualization settings. Requirement: A visualization is selected in the Frame selection input field. |
Selected Frame | Name of the frame to be switched to Example: Hint: Use the Assign selection command for changing the setting here. |
Selected Visu | Name of the switched visualization Example: Hint: Use the Assign selection command for changing the setting here. |
Requirement: The Switch to any visualization option is selected. | |
Frame and visualization selection | Contains the frame to be switched to |
Assign | Frame to be switched to (with complete path). The index determines the visualization. Example: The path is specified in the following syntax: Caution: Visualizations can be nested at any depth by means of frame elements. In order to use the Switch to any visualization frame selection type without any problems, a frame must not contain more than 21 referenced visualizations. |
Assign expression | Variable ( Example: |
Index to select | . Index that determines which of the referenced visualizations is displayed
Note: The referenced visualizations of a frame are indexed automatically according to their order. |
Requirement: The project contains visualizations that form a structure.
Input Action: Write Variable
The configuration of the input action defines how a visualization user specifies a value and to which variable the value is written.
Input type How the input is prompted | |
Default | Input field, or if necessary a virtual keyboard (if the display variant does not have a physical keyboard) Note: The default option for text input at runtime is set in the Visualization Manager: Dialog Settings tab, Settings for Default Text Input. |
Text input | An input field is displayed. As the visualization user, you can use the keyboard to specify a number or a text. Requirement: The display variant has a keyboard as input device. |
Default Keypad | The on-screen keyboard has been selected in the Visualization Manager. It is used for text input. Note about compatibility: This type only works as of version 4.9.0.0 of CODESYS Visualization. Projects which are saved with version 4.9.0.0 and opened later with an earlier version will use the older keyboard/numeric keypad dialogs from the Note: This layout is not supported by the integrated visualization. Hint: If you want to edit more complex data types such as time values, then you can use specially adapted dialogs via Open Dialog (e.g., Note: Only 10 simultaneously open keypads are supported. When more than 10 are opened simultaneously, a warning will be displayed. |
Default Numpad | References the default input in Numpad configured in the Visualization Manager Note about compatibility: This type only works as of version 4.9.0.0 of CODESYS Visualization. Projects which are saved with version 4.9.0.0 and opened later with an earlier version will use the older keyboard/numeric keypad dialogs from the Note: This layout is not supported by the integrated visualization. |
Text input with limits | References the default input in Use text input with limitation configured in the Visualization Manager An input field is displayed. You use the keyboard to specify a number or a text. The field also shows the value range for the input. When a limit is passed, the input value is displayed in red. Requirement: The display variant has a keyboard as input device. The default setting as of version 4.9.0.0 onwards is |
VisuDialogs.Keypad | A virtual keyboard opens. You use it to specify a number or a text. |
VisuDialogs.Keypad2 | It is possible to input data via the integrated keyboard as well as via the physical keyboard. Note about compatibility: This type only works as of version 4.9.0.0 of CODESYS Visualization. Projects which are saved with version 4.9.0.0 and opened later with an earlier version will use the older keyboard/numeric keypad dialogs from the Note: This layout is not supported by the integrated visualization. |
VisuDialogs.Numpad | A virtual keyboard opens. You use it to specify a number. |
VisuDialogs.Numpad2 | It is possible to input data via the integrated keyboard as well as via the physical keyboard. Note about compatibility: This type only works as of version 4.9.0.0 of CODESYS Visualization. Projects which are saved with version 4.9.0.0 and opened later with an earlier version will use the older keyboard/numeric keypad dialogs from the Note: This layout is not supported by the integrated visualization. |
VisuDialogs.NumpadExtended | A virtual keyboard opens. You use it to specify a number. Hexadecimal and exponential notation are also permitted here. |
Choose variable to edit | |
Use text output variable |
|
Use another variable |
Example: |
Initial display format | Placeholder with format definition. It defines the output format for the variable value and the input limits. Example: |
Min | Minimum value of the input limit. If a user specifies a lesser value, then it is not accepted.
|
Max | Maximum value of the input limit. If a user specifies a greater value, then it is not accepted.
|
Dialog title | Text displayed in the title bar of the dialog. Optional.
|
Password field |
|
Position to Open Input Dialog | Initial position for the opening input dialog relative to the calling visualization |
Use global setting (from the Visualization Manager) | Requirement: This option is available only when displaying on a TargetVisu or as a WebVisu.
|
Centered |
|
Position |
Note: Use the corresponding input options for specifying the position in the X-direction and the Y-direction. |
X | Horizontal X-position for the upper left corner of the opening dialog Input options:
|
Y | Vertical Y-position for the upper left corner of the opening dialog Input options:
|
Input action: Execute ST Code
Input field | Editor for code as structured text |
Input action: Toggle Variable
Variable | Variable ( Example: |
Input Action: File Transfer
With the File Transfer input action, a file can be transferred from an operating variant (target or web visualization) to the PLC as well as to and from the PLC. This works either by means of a file transfer (Type: File) or streaming (Type: Streaming).
The action has the effect that a file selection dialog is displayed in the visualization at runtime. There the visualization user can select a file which will be transferred either to or from the PLC: For a transfer from a PLC to the visualization, the Save File dialog opens. For the transfer from the visualization to the PLC, the Open File dialog opens.
Transfer | |
Direction | Direction of file transfer |
From PLC to Visualization | The object specified in File name or Streaming instance name is transferred from the PLC to the visualization. The Save File file selection dialog is displayed in the visualization at runtime. |
From Visualization to PLC | The file specified by the visualization user is transferred to the PLC and saved in the file path specified in File name or Streaming instance name. The Open File file selection dialog is displayed in the visualization at runtime. |
Type | . Determines how the file is transferred
|
Type | File The data transfer is done by file transfer. |
File Name | File path (type
NoteIf a user specifies the file path in the visualization by means of a Text Field element, the masking character NoteIn the case that the file path is specified by the user, it should be checked by the application in order to prevent files from being read or overwritten accidentally. |
Type | Streaming The data transfer is done by streaming. |
Streaming instance name | Instance path (type Type Type |
Control flags | Note: The variable is evaluated only for transfer direction From Visualization to PLC. Variable (type Determines how the object (file or instance object) is handled on the file system of the PLC. Two flags are provided for this with which the variable can be set.
. Options
Example: |
The transfer direction is From Visualization to PLC (write).
Example: A new recipe file Recipes/Recipe_2021.txt has been created in the visualization device. The visualization user selects this file and wants to save the file on the PLC under the same name. Because the control flags are set accordingly, a message window opens and the visualization user can confirm that the file will be overwritten.
PROGRAM PLC_PRG
VAR
xVisuToggle : BOOL;
dwControlFlag : DWORD := VisuElems.VisuEnumFileTransferControlFlags.UseOriginalFileName
+ VisuElems.VisuEnumFileTransferControlFlags.ConfirmFileOverwriteInPlc;
strFileName: STRING := '/Recipes/Recipe_new.txt';
END_VARStatus Variables | |
Transfer active | Boolean variable (optional)
|
Transfer successful | Boolean variable (optional)
|
Error code | . Possible error codes:
Possible causes for missing device support:
|
Use local visualization files | Requirement: The option is available when Transfer visualization files to the PLC has been specified as the direction.
|